MDDF - description
MDDF - description
Multi Dimensional Data Format structure contains 9 variables, where d and TestParameters are the most essential, because they contains the data which can be further processed. The other variables are used for the correct data description – coordinate system, time zone, etc.
MDDF file name following the scheme: MDDF_EPIZODNAME_file_description.
| Variable name | Type | Description |
|---|---|---|
| CRS | char | Coordinate Reference System EPSG code (or local) mapping surveying (http://epsg.io), standard WGS84 (EPSG: 4326) |
| d | struct | The variable containing the data. The data may be as a single variable, a vector or an array. d structure contains the following fields: - Station_codename – Code name of the station - Measurements – Number of measurements or sample collection in the field. Structure containing the following fields: - - Date – Time of measured parameter/sample collection - Tests– Number of test performed/ measured parameters. Structure containing the following fields: - - Test_name_id – Id of measured parameter/test - Result – Result of measured parameter/test - Result_duplicate (optional) – Quality assurance checkStage (optional)– Stage of monitoring - Measurement_method (optional) – Method of measurement |
| dDescription | cell | Description of the fields of ‘d’ variable. A cell contains two columns: the first contains the name of the field/column of data, the second contains a description of them. All data must be specified. |
| Description | char | The text description of the data contained in the file |
| FormatName | char | Name of data format MDDF (Multi Dimensional Data Format). |
| FormatVersion | real | When changing/expansion of the format change its version. It can have one number after the decimal point. |
| TestParameters | struct | The variable containing the parameters of data. The data may be as a single variable, a vector or an array. TestParameters structure contains the following fields: - Test_name – Name of test/measured parameter - Unit – Unit of test/measured parameter - Type – Data type number: An array contains two columns: the first contains the name of the field/column of data, the second contains the data type number. All data must be specified. The Numbers of Data type: 1 – the real data without limits, 2 – the integer data, 3 – text value, 4 – the real number rounded to 0.1 (shown as 11), 5 – time in Matlab format serial time – the time display format; seconds with accuracy 1/10, 6 – the real data display in an engineering manner with one decimal place, e.g.: 3.5E6, (obsolete, recommended 2cd) 7 – the real data display in an engineering manner with two decimal place, (obsolete, recommended 2cd) bc – (b and c are code digits) the real data is displayed in fix-point manner with at minimum b places before decimal and c decimal place, e.g. For number 3.149. 10: „3” 11: „3.1” 12: „3.15” 20: „03” 23: „03.149” 1bc– the same manner as bc, but with place for a sign (space for sign „+”, sign ‘-’ for sign „-”), 2cd– (c and d are code digits), the real data is displayed in an engineering manner, with place for a sign (space for sign „+”, sign ‘-’ for sign „-”), with c decimal place and exponent expressed by d places. The sign in exponent is always displayed. e.g. For number 0.001 211: „1.0E-3” 221: „1.00E-3” 212: „1.0E-03” 222: „1.00E-03” — e.g. For number 1000 211: „1.0E+3” 221: „1.00E+3” 212: „1.0E+03” 222: „1.00E+03” - Technique (optional) – Technique - LOD (optional)– Limit of detection (Lower and Upper) - LODType (optional)– Data type number of LOD - Accreditation (optional) – Accreditation body |
| TestParametersDescription | cell | Description of the fields of ‘TestParameters’ variable. A cell contains two columns: the first contains the name of the field/column of data, the second contains a description of them. All data must be specified. |
| TimeZone | char | Acronym of Time Zone (http://en.wikipedia.org/wiki/List_of_time_zone_abbreviations), normally UTC |
Table 1. The structure of Multi Dimensional Data Format
| variable | Field name | Storage format |
|---|---|---|
| d | Station_codename | char |
| Measurements | struct | |
| Measurements.Date | double | |
| Measurements.Tests | struct | |
| Measurements.Tests.Test_name_id | double | |
| Measurements.Tests.Result | double | |
| Measurements.Tests.Result_duplicate | double | |
| Measurements.Stage | char | |
| Measurements.Measurement_method | char | |
| TestParameters | Test_name | char |
| Unit | char | |
| Type | double | |
| Technique | char | |
| LOD | double | |
| LODType | double | |
| Accreditation | char |
Table 2. The format of fields ‘d’ and ‘TestParameters’ variables
Data details:
‘d’ structure contains the following fields:
Station_codename – Code name of the station
Measurements – Number of measurements or sample collection in the field. Structure containing the following fields:
Date – Time of measured parameter/sample collection
Tests – Number of test performed/ measured parameters.. Structure containing the following fields:
Test_name_id – Id of measured parameter/test
Result – Result of measured parameter/test
Result_duplicate (optional) – Quality assurance check
Stage (optional) – Stage of monitoring
Measurement_method (optional) – Method of measurement
‘TestParameters’ structure contains the following fields:
Test_name – Name of test/measured parameter
Unit – Unit of test/measured parameter
Type – Data type number
Technique (optional) – Technique
LOD (optional) – Limit of detection (Lower and Upper)
LODType (optional) – Data type number of LOD